Customization: | Available |
---|---|
After-sales Service: | Local Network |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
JDEC 500GF-N Biogas Generator Set | |
Genset model | 600GF-N |
Engine model | G12V190ZLTZ-1 |
Alternator model | IFC6 Series or equivalent |
Control panel | GPL 600 |
Rated voltage | 4e40V |
Power factor | 0.8 (lagging) |
Rated frequency | 60Hz |
Rated speed | 1200rpm |
Starting method | 24V DC start |
Voltage regulating method | AVR (Automatic voltage regulation) |
Speed governing method | Electronic governor |
Ignition system | Digital ignition system |
Cooling method | Forced water cooling with multi-fans radiator |
Coupling method | Flexible coupling |
Reference dimension | 5120x2040x2778mm (the drawing will be presented after signing of contract) |
Reference weight | 14800kg |
Biogas Engine Data | |
Model | G12V190ZLTZ-1 |
Engine type | Four strokes, spark plug ignited, water cooled and turbocharged |
Cylinder arrangement | V type, 60° |
Bore | 190mm |
Stroke | 210mm |
Displacement | 71.45L |
Rated speed | 1200rpm |
Idle speed | 700rpm |
Lube oil consumption | ≤0.8g/kwh |
Exhaust temperature (before turbo) | ≤650ºC |
Jacket water outlet temperature | ≤85ºC |
Lube oil temperature in oil pan | ≤90ºC |
Oil pressure in main oil passage | 400-800kpa |
Oil pressure in turbocharger | 200-400kpa |
Steady speed regulation | 0-5% adjustable |
Cooling method | Forced water cooling, multi-fans radiator |
Lubricating method | Pressure and splashing lubricating |
Ignition method | Spark plug ignition |
Starting method | 24V DC start |
Rotating direction | Counterclockwise (flywheel view) |
Output method | Flywheel output |
Alternator Data | |
Model | 1FC series or equivalent |
Rated capacity | 750kva |
Rated voltage | 440V |
Rated frequency | 60Hz |
Power factor | 0.8 (lagging) |
Rated speed | 1200rpm |
Protection class | IP23 |
Insulation class | H |
Phases and connection | 3 phases and 4 wires |
Exciting method | Brushless |
Voltage regulating method | AVR automation |
Steady state voltage regulation ratio | ≤±2.5% |
Transient voltage regulation ratio | ≤+20% (-15%) |
Voltage settling time | ≤ 1.5s |
Voltage fluctuation ratio | ≤1% |
Steady state frequency regulation ratio | 0-5% |